A linear actuator is a common electro-mechanical component used in many applications. The unit is highly customizable and can be modified to fit into different environments and meet various functional demands. To utilize linear actuators positional feedback feature, there are many sensors available for this function. In this article, we will discuss how does limit switch feedback work in actuators.

Limit Switch in Linear Actuators

First, we will take a look at how does limit switch works inside a linear actuator. A limit switch is a component that is responsible for ensuring the device does not extend nor retract outside its mechanical dimension. An electric linear actuator moves as its motor spin, which drives the acme screw to push the shaft rod out or pull it in. The direction of the motor spin determines the direction of the shaft rod movement. However, by itself, there are no stop points on neither end of the travel. The motor will only stop when the user manually turns off the power to the unit. This can cause a safety concern if the actuator traveled to its mechanical limitation but the motor is still running, the unit will cause a motor stall. This will cause a high current draw, and eventually burn out the motor. To prevent this, a set of limit switches are installed in all Progressive Automations actuators. The limit switch implements a mechanical trigger at either end of the travel, and the trigger causes the motor to shut off and then end of travel.

Limit Switches for actuators

Limit Switch Feedback in Linear Actuators

Some users’ application needs the limit switch feedback signals to control their system. Instead of using the mechanical trigger to shut off the motor, the application prefers to have an analog signal as part of an integrated control system. Currently, Progressive Automations offer two different configurations when it comes to limit switch feedback.

Option 1:

The 'Common' for both signals are separated. The extended limit switch and the retracted limit switch will provide an individual signal of normally open and closed to the users. The control system then can take that signal to monitor the positions and drive the motor to stop at the fully extended and retracted position.

Limit switches for actuators

Option 2:

Very similar to option 1, except now the extended and retracted limit switch shares a common signal. This will still provide the same open and closed state, but with one less wire involved.

Both of these configurations can provide the signal needed to turn on or off the indicator light and also notify the user that the unit has reached its final position. This is a common application for assembly line machinery, where the operator is usually away from the actuator, they rely on the control panel indicators to alert them on the state of the operation. This can also be used as redundancy in a control loop, to provide extra safety assurance to the user.

The Feedback from limit switches can help the user be more informed of the state of their application. This is just one of many ways a linear actuator can provide additional information needed to improve the functionality of a system. For further information and other feedback options, please visit our website or contact us at sales@progressiveautomations.com.